Compatible CT X-Ray Tube for GE Performix Ultra D3885T

ModelPerformix Ultra

Compatible CT X-ray tube for GE Performix Ultra D3885T and selected BrightSpeed, LightSpeed, Optima and Discovery systems, featuring 6.3 MHU heat capacity, 140 kV and ball-bearing technology.

  • Photo VerificationProduct photos & identification available for verification
  • Inspection ArrangementsPre-shipment inspection can be arranged where applicable
  • Worldwide SupplyInternational shipping can be arranged

Technical Specifications

Warranty3 Months
Compatible OEM ReferenceGE Performix Ultra / D3885T
Related OEM Reference2137130-13
Bearing TypeBall Bearing

Product Identification

ModelPerformix Ultra
PlatformGE BrightSpeed / LightSpeed / Optima CT
ConditionNew
ClassificationCT Spare Parts
TypeCT X-Ray Tubes
Compatible SystemsSelected GE BrightSpeed Edge, BrightSpeed Elite, BrightSpeed Excel, BrightSpeed 8/16, LightSpeed 16, Optima CT540, Optima CT660, Discovery PET/CT 600, Discovery RX and selected HiSpeed CT systems. Final compatibility should be confirmed using the exact system model, existing tube identification and system configuration.
BrandUnknown

Product Overview

Product Overview This compatible CT X-ray tube assembly is designed as a replacement option for selected GE CT systems associated with the Performix Ultra tube family, including OEM reference D3885T. Featuring a 6.3 MHU heat capacity, 140 kV nominal voltage and a ball-bearing rotating anode design, the tube is intended for selected GE BrightSpeed, LightSpeed, Optima and Discovery CT applications. The product is supplied as a new compatible replacement. Exact compatibility should be confirmed using the CT system model, existing tube identification, OEM reference and system configuration before ordering. OEM Reference & Compatibility

  • OEM Tube Family: GE Performix Ultra
  • Primary OEM Reference: D3885T
  • Related GE Reference: 2137130-13
  • Product Type: Compatible CT X-Ray Tube Assembly
  • Bearing Type: Ball Bearing
  • Condition: New

This product is a compatible replacement and is not an original GE HealthCare X-ray tube. Key Features

  • 6.3 MHU heat capacity
  • 140 kV nominal voltage
  • Ball-bearing rotating anode design
  • Dual focal spot configuration
  • Up to 53.2 kW nominal anode input power
  • 3.7 kW nominal continuous input power
  • Designed for selected GE BrightSpeed, LightSpeed, Optima and Discovery systems
  • New compatible replacement tube assembly

Technical Specifications

  • Product Type: CT X-Ray Tube Assembly
  • Heat Capacity: 6.3 MHU
  • Nominal Voltage: 140 kV
  • Large Focus Size: 1.2 × 1.1 mm
  • Small Focus Size: 0.9 × 0.7 mm
  • Nominal Anode Input Power: 24 kW / 53.2 kW
  • Nominal Continuous Input Power: 3.7 kW
  • Bearing Type: Ball Bearing
  • Condition: New

Ball-Bearing Design The ball-bearing rotating anode design provides a proven and cost-effective solution for compatible CT applications requiring reliable high-speed rotation and rapid scan cycling. The design is suitable for supported GE CT systems where a ball-bearing tube configuration is required. Compatible CT Systems Designed for selected configurations including:

  • GE BrightSpeed Edge
  • GE BrightSpeed Elite
  • GE BrightSpeed Excel
  • GE BrightSpeed 8
  • GE BrightSpeed 16
  • GE LightSpeed 16
  • GE Optima CT540
  • GE Optima 540
  • GE Optima CT660
  • GE Discovery PET/CT 600
  • GE Discovery RX
  • Selected GE HiSpeed CT configurations

Compatibility may vary according to system generation, tube configuration and hardware revision. Final compatibility should therefore be confirmed using the existing tube information before quotation and shipment. Compatibility Verification To ensure the correct replacement tube is selected, please provide:

  • CT manufacturer and system model
  • Existing X-ray tube model
  • Existing OEM P/N or reference number
  • X-ray tube nameplate photo
  • Clear photos of the existing tube assembly
  • System serial number, if required for verification

VISTAING MEDICAL can review the supplied information and confirm the appropriate compatible replacement before quotation. Compatible Replacement Notice This product is a compatible replacement CT X-ray tube assembly intended for applicable GE CT systems. It is not an original GE HealthCare X-ray tube. GE product names, CT system models and OEM reference numbers are used only for compatibility identification. Product appearance, labeling and certain specifications may vary according to the confirmed supply configuration or production batch. Supply & Inspection Availability is confirmed according to the required CT system and tube configuration. Actual product photos and identification information can be provided before shipment when available. Compatibility can also be checked against the customer's existing tube and system information before order confirmation. Warranty A standard 3-month warranty is available. Final warranty coverage and terms are confirmed in the quotation or sales agreement. Request a Quote For quotation and compatibility confirmation, please provide:

  • GE CT system model
  • Existing X-ray tube model
  • Existing OEM P/N / reference number
  • Tube nameplate photo
  • Required quantity
  • Destination country

Contact VISTAING MEDICAL for availability, compatibility confirmation and international supply.

Compatible Systems

Selected GE BrightSpeed Edge, BrightSpeed Elite, BrightSpeed Excel, BrightSpeed 8/16, LightSpeed 16, Optima CT540, Optima CT660, Discovery PET/CT 600, Discovery RX and selected HiSpeed CT systems. Final compatibility should be confirmed using the exact system model, existing tube identification and system configuration.
Chat with us on WhatsApp

Inquiry Submitted Successfully!

Thank you for your inquiry. Our team will review your request and contact you with the available information.